Co2 Laser Controller FAQ
Frequently Asked Questions Case 1
Automatically returns to home position when processing starts
Troubleshooting
1.Reset settings are incorrect
2.Reset button on control panel not working
3.Power supply is unstable or too low
4.System software is corrupted
Quick Solution Guide
First, check if the reset parameters are normal, verify whether the user parameter reset is enabled, ensure the mainboard wiring is not under-voltage, and confirm that the output port is functioning properly.
Frequently Asked Questions Case 2
The machine does not return to the positioning point after processing
Troubleshooting
1.Multiple positioning points are enabled
2.The positioning button on the panel is malfunctioning or the positioning button was not pressed to initiate positioning
3.Incorrect return position settings in user parameters
Quick Solution Guide
Check if the corresponding items are set incorrectly
Frequently Asked Questions Case 3
Laser pulse works, but no laser during cutting
Troubleshooting
1.Layer output settings are incorrect, laser enable for the layer is not turned on.
2.The laser power setting for the layer is too low.
3.Incorrect head offset settings.
Quick Solution Guide
1.Even after increasing the power, there is still no laser output, although the cutting action is normal.
2.The number of heads is set to 2, but there is actually only one laser head.